Simultaneous estimation of zinc carnosine and aceclofenac in bulk and tablet dosage form by HPLC method

  • G.Chandra Mohan Rao Annamacharya college of Pharmacy, New boyanapalli, Rajampet, Kadapa Dist., Andhra Pradesh, India
  • K.Gnanaprakash Annamacharya College of Pharmacy, Rajampet-516126, Kadapa Dist, A.P., India
  • M.Alagusundaram Annamacharya College of Pharmacy, Rajampet, Kadapa-District, Andhrapradesh, India
  • V.S.T.Rajan Annamacharya College of Pharmacy, Rajampet, Kadapa-District, Andhrapradesh, India
  • A.V.Badarinath Annamacharya College of Pharmacy, Rajampet, Kadapa-District, Andhrapradesh, India
  • C.Madhusudhanachetty Annamacharya College of Pharmacy, Rajampet, Kadapa-District, Andhrapradesh, India

Abstract

A simple, precise, rapid and accurate HPLC method developed for the simultaneous estimation of Zinc carnosine and Aceclofenac in tablet dosage form. An C-18 column with 250x4.6mm, 5µm particle size with mobile phase consisting of a mixture of potassium di-hydrogen phosphate buffer, Acetonitrile, methanol in the ratio of 50:30:20 v/v was used. The flow rate was 1.0 ml/min and detection carried out by using U.V visible detector at 215 and 275nm .The retention time were 2.258 for Zinc carnosine, and 6.690min for Aceclofenac. The detector response was linear for Zinc carnosine and Aceclofenac in the concentration range of 2 to 10μg/ml for both drugs. The limit of detection (LOD) for Zinc carnosine and Aceclofenac were found to be 33.4ng/ml and 101.3ng/ml respectively. The limit of quantification (LOQ) for Zinc carnosine and Aceclofenac were found to be 2.473ng/ml and 7.495ng/ml respectively. The percentage assay of Zinc carnosine and Aceclofenac was 99.82% and 99.92% respectively. The method was validated by determining its linearity, precision, accuracy, system suitability in accordance with ICH guidelines. The results of the study showed that the proposed HPLC method is simple, rapid, precise and accurate, which is useful for the routine determination of Zinc carnosine and Aceclofenac in bulk drug and its pharmaceutical dosage forms.

Keywords: Zinc carnosine, Aceclofenac, HPLC, validation, Tablet

Downloads

Download data is not yet available.
Published
2011-07-20
Citations
How to Cite
G.Chandra Mohan Rao, K.Gnanaprakash, M.Alagusundaram, V.S.T.Rajan, A.V.Badarinath, & C.Madhusudhanachetty. (2011). Simultaneous estimation of zinc carnosine and aceclofenac in bulk and tablet dosage form by HPLC method. International Journal of Research in Pharmaceutical Sciences, 2(3), 429-433. Retrieved from https://pharmascope.org/index.php/ijrps/article/view/900
Section
Original Articles
Article Level Metrix
Abstract Views: 5
PDF Downloaded: 2